Features
Applications
|
![]() |
Items |
Characteristics |
||
Rated capacitance range CR |
10 … 82.000 µF |
||
Capacitance tolerance |
± 20% |
||
Rated voltage range UR |
16 … 450 V |
||
Surge voltage US |
UR ≤ 315 V: US = 1,15 UR UR > 315 V: US = 1,10 UR |
||
Max. reverse voltage |
2 V |
||
Category temperature range |
- 40°C ... + 105 °C |
||
Leakage current IL after 5 min @ UR |
≤ 0,008 * CR [µF] * UR [V] + 6 µA [µA] |
||
Useful life
|
3000 h@ 105 °C ; UR ; IR~ |
Requirements Δ C/C ≤ 30 %of initial value ESR ≤ 300 % of specified limit IL ≤ specified limit |
|
Endurance test
|
2000 h @ 105 °C , UR |
Requirements Δ C/C ≤ 20 % of initial value ESR ≤ 130 % of specified limit IL ≤ specified limit |
|
Climatic category IEC 60068 |
40/105/56 |
||
Voltage proof of the external insulation |
D ≤ 25 mm: ≥ 1000 V AC D > 25 mm: ≥ 2500 V AC |
||
Sectional specification |
IEC 60384-4 |
||
Øleads |