Serie ATBIG - 40°C ... + 85°C (5000 h)
Features
Applications
|
![]() |
Items |
Characteristics |
|
Rated capacitance range CR |
1… 200 µF @ 1 kHz |
|
Capacitance tolerance |
±10%;± 5% on request |
|
UR bipolar (rated voltage DC) |
35 V dc @ 23 V ac 50 V dc @ 35 V ac 70V dc @ 50 V ac |
|
Max. peak voltage (AC) |
May not exceed rated voltage (DC) |
|
Category temperature range |
- 40°C ... + 85 °C |
|
Useful life
|
> 5000 h@ 85 °C > 1000 h@105 °C |
Requirements Δ C/C ≤ 30 %of initial value ESR ≤ 300 % of specified limit IL ≤ specified limit |
Endurance test
|
100 000 h @40 °C |
Requirements Δ C/C ≤ 20 % of initial value ESR ≤ 130 % of specified limit IL ≤ specified limit |
Climatic category IEC 60068 |
40/085/56 |
|
Voltage proof of the external insulation |
D ≤ 25 mm: ≥ 1000 V AC D > 25 mm: ≥ 2500 V AC |
|
Øleads |
Up to 25 mm Ø : 0,8 mm ; more than 25 mm Ø : 1,0 mm |
|